Correct Debugging Tongda Analysis Machine

The Tongda analysis machine can separate the metal materials in the raw materials, but I think the Tongda analyzer needs a critical adjustment process before work, and adjusts according to the size of the metal materials in the raw materials. Stable and efficient separation of metal materials, so how does the Tongda analyzer adjust to make everything work?

1. Ensure that the Tongda analyzer is installed correctly and the feet are firmly installed;

2. Ensure that there is no large piece of metal material directly under the test head;

3. Ensure that the switching power supply of the machine and equipment is correct, and the grounding device is kept good;

4. Enable the main power switch of the Tongda analyzer; the indicator light is on, and the machine starts to be fully automatic and stable. At this time, the light bar will light up and then gradually disappear. When only a few green parts of the light-emitting indicator strip are smoothly flashing, the machine can enter the detection working state;

5. Adjust the sensitivity knob to the middle position and adjust the product compensation knob to the specific position of 2.75.

6. Start the conveyor belt and pass the measured object through the inspection head to observe the state of the two data signals. If the product effect data signal is small, use the detection block to test the sensitivity of the specific situation. If the standard can be reached, the normal value detection can be performed. If the product effect is relatively large, reduce the sensitivity of the data signal with a large effect to zero (counterclockwise to the end);

7. Adjust the Tongda analysis machine compensation knob. When the measured object passes the detection head, the size of the data signal indicated by the light-emitting prompt bar will change. If the data signal increases, debug in the opposite direction until the light bar indicator The product effect is the smallest, and the position of the product compensation at the moment is the most ideal location;

8. Adjust the sensitivity adjustment knob of the two data signals clockwise to improve the detection sensitivity, so that only the green indicator light is on when the metal-free product passes the detection head (the machine will alarm when the red indicator light is on), and then The detection block is used to detect the sensitivity status of the machine equipment test, and after entering the standard, the normal value detection is performed.